M Series

Built-in GPRS modem RTUs for telecontrol of MV transformation centers.

Product highlights

  • 3G/E-GSM/GPRS Quad Band 850/90071800/1900 MHz (Class 10) built-in modem
  • 2 SIM cards support: 1 internal, 1 external or 2 internal
  • High scalability
  • Multiple communication ports to control center or IEDs: GPRS, Ethernet, RS232, RS485 and RS422
  • iRTU devices provide I/O capabilities for direct data acquisition which can be expanded by using iRTUe devices
  • Availability of a wide range of communication protocols to Control Center (IEC60870-5-101/104, DNP3.0, Modbus), and to IEDs (IEC61850, IEC60870-5-101/102/103/104, DNP3.0, Modbus, DLMS)

Technical features

The M Series products are the ideal solution for telecontrol of MV transformation centers. M Series products can collect data from transformation centers, either via direct acquisition (through their digital and analog inputs), or through communication protocol with the bay bus via serial channels (RS422/RS485) using IEC60870-5-102, Procome, Modbus RTU, DNP3.0, etc.

Communication with the Control Center can be done via an IP based channel, the GPRS network. This allows the transfer of information through multiple IP based protocols, such as IEC60870-5-104, DNP3.0 TCP, ModbusTCP, IEC61850 or serial protocols tunneled through TCP. In addition to these advantages, the system features an easy deployment thanks to the connection to a public operator network, that frees the utility from expensive investments.

M0 series units are equipped with an internal dual-SIM GPRS modem which is controlled by the RTU firmware. The use of dual-SIM allows working with two different communications operators, in order to have a backup network in case the main one fails.

3G option is also available in M1 Series.

Control architectures based on M Series control units allow an optimal automation of the Medium Voltage network, at a competitive price.

  • M0 Series: GSM/GPRS Quad Band 850/90071800/1900 MHz (Class 10) internal modem
  • M1 Series: 3G internal modem
  • 2 SIM cards support: 1 internal, 1 external or 2 internal
  • High scalability
  • High I/O density. I/O capabilities can be expanded with iRTUe modules connected through EXP422 port
  • Multiple communication ports including: Ethernet, RS232, RS485 and RS422
  • Protocols to Control Center:
    • IEC60870-5-101
    • IEC60870-5-104 (ETH and serial PPP)
    • IEC61850
    • DNP3.0 Level 4 (Serial and TCP)
    • Modbus RTU/TCP
  • Protocols to IEDs:
    • IEC60870-5-101
    • IEC60870-5-102
    • IEC60870-5-103
    • IEC60870-5-104
    • IEC61850
    • DNP3.0 Level 1 (Serial and TCP)
    • Modbus RTU/TCP
    • DLMS
    • Procome
  • Local maintenance (through USB port) and remote maintenance (Telnet and FTP), with the highest levels of security
  • Procedures, filters and logical formulas available to apply to any signal
  • Omega DIN rail mounting
  • 2.5kV insulation in the power supply, I/O and serial ports
  • Extended temperature range
  • Complies with all electrical, electromagnetic compatibility and environmental standards required by the power industry
Tecnical Specifications

Communications


  • (4) Serial port (3kV isolation) with TX/RX LED indicators:
    • (1) Full RS232/RS422/RS485 software configurable
    • (2) RS422/RS485 software configurable
    • (1) EXP422 for connection with iRTUe devices
  • (1) Ethernet 10/100BaseTX port (RJ45)
  • Other:
    • (1) USB port to connect peripheral devices (USB drives, printers, etc.)
    • (1) Management (MGMT) port (MiniUSB connector) for PC connection (local maintenance)
    • (1) MicroSD internal slot for up to 32Gb data storage
  • Technical Specifications of embedded GPRS modem (M0 Series):
    • E-GSM/GPRS Quad Band 850/90071800/1900 MHz (Class 10), dual SIM modem
    • Optionally, EDGE and 3G (M1 Series) are also supported
    • Antenna connector: female SMA, 50 Ohm
    • Approvals: GFC-CC, PTCRB, R&TTE (CE), FCC
  • Protocols to Control Center:
    • IEC60870-5-101
    • IEC60870-5-104 (ETH and serial PPP)
    • IEC61850
    • DNP3.0 Level 4 (serial, UDP, TCP and TCP Dual)
    • Modbus RTU/TCP
  • Protocols to IEDs (meters, protection relays, etc.):
    • IEC60870-5-101
    • IEC60870-5-102
    • IEC60870-5-103
    • IEC60870-5-104
    • IEC61850
    • DNP3.0 Level 1 (serial and TCP)
    • Modbus RTU/TCP
    • DLMS
    • Procome

-top of specifications-

I/O Configuration


  • Different I/O configurations, both digital and analog (24DI, 8 relays, 8 AI, …)
  • iRTU units are equipped with internal I/O module. Available configurations:
    • C1: 8 DI (Digital Inputs) + 4 output relays + 2 AI (Analog Inputs, 20 mA)
    • D1: 24 DI (Digital Inputs)
    • Other configurations available
  • I/O capabilities can be expanded with iRTUe expansion devices. Options:
    • iRTUe-D1D1: 48 DI (Digital Inputs)
    • iRTUe-D1R1: 24 DI (Digital Inputs) + 8 output relays
    • iRTUe-D1A1: 24 DI (Digital Inputs) + 8 AI (Analog Inputs, 20 mA)
    • Other configurations available

-top of specifications-

Power Supply


  •  Power supply options: 12 Vdc, 24Vdc, 48Vdc or 125 Vdc (-20%, + 15%). Contact iGrid T&D for other power supply options.
  • 2.5kV dielectric insulation
  • Reversible polarity

-top of specifications-

Applications and Maintenance


iRTU & iGW units allow maintenance and configuration tasks to be performed, both locally and remotely over the IP network. Performance of maintenance tasks may be accomplished by using standard software tools, e.g.:

  • Communication trace display: Telnet manager (HyperTerminal or similar)
  • Data uploading or downloading: FTP manager (Windows File Explorer or similar)
  • iConf tool for configuration and management of iRTU/iGW units

-top of specifications-

Physical Characteristics


  •  DIN rail mounting
  • Interconnection between iRTU/iGW unit and iRTUe devices through 6-wire patch cable with RJ12 connectors
  • Physical dimensions: 173x137x78.4 mm
  • Weight: 900gr

-top of specifications-

Environmental Conditions


  • Operating Temperature: -20º to +70ºC
  • Humidity: 93% non-condensing at 55ºC

-top of specifications-

Regulations


  •  EN55022: Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
  • EN61850: Communication networks and systems in substations
  • EN60255-5: Electrical Relays. Insulation Coordination for Measuring Relays and Protection Equipment. Requirements and Tests
  • IEC6100-4 , IEC6100-6-4/5: Electromagnetic Compatibility (EMC)
  • IEC60870-2-2: Telecontrol equipment and systems. Operating conditions. Environmental conditions
  • IEC60950-1: Information technology equipment. Safety. General requirements
  • RoHS compliant

-top of specifications-